Actively exploited

CVE-2025-6543 Citrix NetScaler ADC and Gateway Buffer Overflow Vulnerability

Citrix NetScaler ADC and Gateway contain a buffer overflow vulnerability leading to unintended control flow and Denial of Service. NetScaler must be configured as Gateway (VPN virtual server, ICA Proxy, CVPN, RDP Proxy) OR AAA virtual server.

From the CISA KEV catalogue version 2026.11.06, with Cybergen analysis. Updated 6 Nov 2026.

Our Assessment

Should You Worry?

Patch nowCybergen assessment
  • CISA confirmed exploitation in the wild and added it to the Known Exploited Vulnerabilities catalogue on 30 Jun 2025.
  • Rated Critical severity (CVSS 9.2, scored by Vendor).
  • This product type is often exposed to the internet, which is where attackers scan for it first.
  • It has been in the catalogue for 494 days. Systems still unpatched now have almost certainly been scanned for it.
The Vulnerability

What It Is

Memory overflow vulnerability leading to unintended control flow and Denial of Service in NetScaler ADC and NetScaler Gateway when configured as Gateway (VPN virtual server, ICA Proxy, CVPN, RDP Proxy) OR AAA virtual server

Affected Versions

ProductVersions
NetScaler ADC14.1 to before 47.46
13.1 to before 59.19
13.1 FIPS and NDcPP to before 37.236
NetScaler Gateway14.1 to before 47.46
13.1 to before 59.19
13.1 FIPS and NDcPP to before 37.236

From the public CVE record, as supplied by the vendor. Always confirm against the vendor advisory.

From Watch to Action

What To Do Now

  1. 1

    Find it

    Search your asset inventory and external attack surface for Citrix NetScaler ADC and Gateway. Include cloud images, appliances and anything a supplier runs for you.

    Attack Surface Management
  2. 2

    Fix it

    Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

    Vulnerability Management
  3. 3

    Hunt for compromise

    If an affected system was reachable before you patched, assume it may have been hit. Check logs, new accounts, web shells and outbound connections from the date of exposure.

    Incident Response
  4. 4

    Prove it is fixed

    Rescan or test the system after patching. Upgrades that fail silently and forgotten secondary instances are common.

    Penetration Testing

Not Sure If You Are Exposed?

Our attack surface and vulnerability teams can check your internet-facing estate for CVE-2025-6543 and every other exploited flaw on the list.

Check My Exposure