Actively exploited

CVE-2024-8956 PTZOptics PT30X-SDI/NDI Cameras Authentication Bypass Vulnerability

PTZOptics PT30X-SDI/NDI cameras contain an insecure direct object reference (IDOR) vulnerability that allows a remote, attacker to bypass authentication for the /cgi-bin/param.cgi CGI script. If combined with CVE-2024-8957, this can lead to remote code execution as root.

From the CISA KEV catalogue version 2026.11.06, with Cybergen analysis. Updated 6 Nov 2026.

Our Assessment

Should You Worry?

Patch nowCybergen assessment
  • CISA confirmed exploitation in the wild and added it to the Known Exploited Vulnerabilities catalogue on 4 Nov 2024.
  • Rated Critical severity (CVSS 9.1, scored by Vendor).
  • It has been in the catalogue for 732 days. Systems still unpatched now have almost certainly been scanned for it.
The Vulnerability

What It Is

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.

Affected Versions

ProductVersions
PTZOptics PT30X-SDIbefore 6.3.40
PTZOptics PT30X-NDIbefore 6.3.40

From the public CVE record, as supplied by the vendor. Always confirm against the vendor advisory.

From Watch to Action

What To Do Now

  1. 1

    Find it

    Search your asset inventory and external attack surface for PTZOptics PT30X-SDI/NDI Cameras. Include cloud images, appliances and anything a supplier runs for you.

    Attack Surface Management
  2. 2

    Fix it

    Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

    Vulnerability Management
  3. 3

    Hunt for compromise

    If an affected system was reachable before you patched, assume it may have been hit. Check logs, new accounts, web shells and outbound connections from the date of exposure.

    Incident Response
  4. 4

    Prove it is fixed

    Rescan or test the system after patching. Upgrades that fail silently and forgotten secondary instances are common.

    Penetration Testing
Stay Ahead

More Exploited PTZOptics Flaws

Get alerts for PTZOpticsWe email you when a new PTZOptics vulnerability is confirmed as exploited. Add more vendors on Threat Watch.

By signing up you agree to receive Threat Watch alerts. Unsubscribe at any time. See our Privacy Policy.

All 2 exploited PTZOptics vulnerabilities

Not Sure If You Are Exposed?

Our attack surface and vulnerability teams can check your internet-facing estate for CVE-2024-8956 and every other exploited flaw on the list.

Check My Exposure