Actively exploited

CVE-2023-45727 North Grid Proself Improper Restriction of XML External Entity (XXE) Reference Vulnerability

North Grid Proself Enterprise/Standard, Gateway, and Mail Sanitize contain an improper restriction of XML External Entity (XXE) reference vulnerability, which could allow a remote, unauthenticated attacker to conduct an XXE attack.

From the CISA KEV catalogue version 2026.11.06, with Cybergen analysis. Updated 6 Nov 2026.

Our Assessment

Should You Worry?

Patch urgentlyCybergen assessment
  • CISA confirmed exploitation in the wild and added it to the Known Exploited Vulnerabilities catalogue on 3 Dec 2024.
  • Rated High severity (CVSS 7.5, scored by CISA).
  • It has been in the catalogue for 703 days. Systems still unpatched now have almost certainly been scanned for it.
The Vulnerability

What It Is

Proself Enterprise/Standard Edition Ver5.62 and earlier, Proself Gateway Edition Ver1.65 and earlier, and Proself Mail Sanitize Edition Ver1.08 and earlier allow a remote unauthenticated attacker to conduct XML External Entity (XXE) attacks. By processing a specially crafted request containing malformed XML data, arbitrary files on the server containing account information may be read by the attacker.

Affected Versions

ProductVersions
North Grid Corporation Proself Enterprise/Standard EditionVer5.62 and earlier
North Grid Corporation Proself Gateway EditionVer1.65 and earlier
North Grid Corporation Proself Mail Sanitize EditionVer1.08 and earlier

From the public CVE record, as supplied by the vendor. Always confirm against the vendor advisory.

From Watch to Action

What To Do Now

  1. 1

    Find it

    Search your asset inventory and external attack surface for North Grid Proself. Include cloud images, appliances and anything a supplier runs for you.

    Attack Surface Management
  2. 2

    Fix it

    Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

    Vulnerability Management
  3. 3

    Hunt for compromise

    If an affected system was reachable before you patched, assume it may have been hit. Check logs, new accounts, web shells and outbound connections from the date of exposure.

    Incident Response
  4. 4

    Prove it is fixed

    Rescan or test the system after patching. Upgrades that fail silently and forgotten secondary instances are common.

    Penetration Testing
Stay Ahead

More Exploited North Grid Flaws

Get alerts for North GridWe email you when a new North Grid vulnerability is confirmed as exploited. Add more vendors on Threat Watch.

By signing up you agree to receive Threat Watch alerts. Unsubscribe at any time. See our Privacy Policy.

Not Sure If You Are Exposed?

Our attack surface and vulnerability teams can check your internet-facing estate for CVE-2023-45727 and every other exploited flaw on the list.

Check My Exposure