Actively exploited

CVE-2023-4346 KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability

KNX Association KNX Protocol Connection Authorization Option 1 contains an overly restrictive account lockout mechanism vulnerability that could allow an attacker to purge all devices without additional security options enabled and set a BCU key to lock the device.

From the CISA KEV catalogue version 2026.11.06, with Cybergen analysis. Updated 6 Nov 2026.

Our Assessment

Should You Worry?

Patch urgentlyCybergen assessment
  • CISA confirmed exploitation in the wild and added it to the Known Exploited Vulnerabilities catalogue on 15 Jul 2026.
  • Rated High severity (CVSS 7.5, scored by Vendor).
  • It has been in the catalogue for 114 days. Systems still unpatched now have almost certainly been scanned for it.
The Vulnerability

What It Is

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.

Affected Versions

ProductVersions
KNX Association KNX Protocol Connection Authorization Option 1See the vendor advisory

From the public CVE record, as supplied by the vendor. Always confirm against the vendor advisory.

From Watch to Action

What To Do Now

  1. 1

    Find it

    Search your asset inventory and external attack surface for KNX Association KNX Protocol Connection Authorization Option 1. Include cloud images, appliances and anything a supplier runs for you.

    Attack Surface Management
  2. 2

    Fix it

    Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

    Vulnerability Management
  3. 3

    Hunt for compromise

    If an affected system was reachable before you patched, assume it may have been hit. Check logs, new accounts, web shells and outbound connections from the date of exposure.

    Incident Response
  4. 4

    Prove it is fixed

    Rescan or test the system after patching. Upgrades that fail silently and forgotten secondary instances are common.

    Penetration Testing
Stay Ahead

More Exploited KNX Association Flaws

Get alerts for KNX AssociationWe email you when a new KNX Association vulnerability is confirmed as exploited. Add more vendors on Threat Watch.

By signing up you agree to receive Threat Watch alerts. Unsubscribe at any time. See our Privacy Policy.

Not Sure If You Are Exposed?

Our attack surface and vulnerability teams can check your internet-facing estate for CVE-2023-4346 and every other exploited flaw on the list.

Check My Exposure