CVE-2021-22681 Rockwell Multiple Products Insufficient Protected Credentials Vulnerability

Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.

From the CISA KEV catalogue version 2026.11.06, with Cybergen analysis. Updated 6 Nov 2026.

Our Assessment

Should You Worry?

Patch nowCybergen assessment
  • CISA confirmed exploitation in the wild and added it to the Known Exploited Vulnerabilities catalogue on 5 Mar 2026.
  • Rated Critical severity (CVSS 9.8, scored by CISA).
  • It has been in the catalogue for 246 days. Systems still unpatched now have almost certainly been scanned for it.
The Vulnerability

What It Is

Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.

Affected Versions

ProductVersions
Rockwell Automation Studio 5000 Logix Designer, RSLogix 5000, Logix ControllersRSLogix 5000 Versions 16 through 20
Studio 5000 Logix Designer: Versions 21 and later
CompactLogix 1768, 1769, 5370, 5380, 5480
ControlLogix 5550, 5560, 5570, 5580
DriveLogix 5560, 5730, 1794-L34
Compact GuardLogix 5370, 5380

From the public CVE record, as supplied by the vendor. Always confirm against the vendor advisory.

From Watch to Action

What To Do Now

  1. 1

    Find it

    Search your asset inventory and external attack surface for Rockwell Multiple Products. Include cloud images, appliances and anything a supplier runs for you.

    Attack Surface Management
  2. 2

    Fix it

    Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

    Vulnerability Management
  3. 3

    Hunt for compromise

    If an affected system was reachable before you patched, assume it may have been hit. Check logs, new accounts, web shells and outbound connections from the date of exposure.

    Incident Response
  4. 4

    Prove it is fixed

    Rescan or test the system after patching. Upgrades that fail silently and forgotten secondary instances are common.

    Penetration Testing
Stay Ahead

More Exploited Rockwell Flaws

Get alerts for RockwellWe email you when a new Rockwell vulnerability is confirmed as exploited. Add more vendors on Threat Watch.

By signing up you agree to receive Threat Watch alerts. Unsubscribe at any time. See our Privacy Policy.

Not Sure If You Are Exposed?

Our attack surface and vulnerability teams can check your internet-facing estate for CVE-2021-22681 and every other exploited flaw on the list.

Check My Exposure